- Debarking Control: As a log moves toward the debarker, an EZ-ARRAY receiver determines the total number of beams that are blocked. It sends an analog signal to the debarking station logic controller, which determines the diameter of the log and adjusts the log grippers and debarking blades to the log`s size.
- Tire Sorting: The closely spaced infrared beams of the EZ-ARRAY measuring light curtain determines the inner and outer diameters of the tire and sends the measurements to a PLC using a MODBUS RTU-485 protocol.
- Carton Sizing: Cartons moving on a conveyor pass between three pairs of EZ-ARRAY measuring light curtains. The total number of beams blocked for each pair indicates the size, which s sent to a sorter as an analog signal. A PLC then diverts each carton to the appropriate storage location. |